This is a module for the MagicMirror².
A Module for MagicMirror² designed to integrate with a SolarEdge System. Dependent on your configuration it can display several statistics.
- Current Power (dependent on yout module update interval)
- more will follow...
Go to your MagicMirror folder.
cd modules
git clone https://github.com/st3v0rr/MMM-SolarEdge.git
cd MMM-SolarEdge
npm iWait until npm has finished.
cd ~/MagicMirror/modules/MMM-SolarEdge
git pull
npm installTo use this module, add the following configuration block to the config/config.js file:
{
module: 'MMM-SolarEdge',
position: 'lower_third',
config: {
apiKey: "################################", //Requires your own API Key
siteId: "12345" //SolarEdge site ID
}
}Upgrading from an older version:
userName,userPasswordandliveDataUrlare gone. They belonged to the portal endpointmonitoring.solaredge.com/solaredge-apigw/..., which SolarEdge retired - it now answers410 Gone. The module reads the power flow from the official API endpoint instead, and can optionally read it from the inverters over Modbus/TCP. Leftover entries in your config are ignored, the module only logs a warning.
Everything comes from the v1 monitoring API. That API grants 300 requests per site and day across all endpoints, and the default intervals are picked so a day fits inside that budget:
| Endpoint | Interval | Requests per day |
|---|---|---|
| Power flow | 8 min (updateInterval, raised from 5 s) |
181 |
| Overview | 30 min (updateIntervalBasicData) |
49 |
| Day energy | 30 min (updateIntervalBasicData) |
48 |
| Details | once at startup | 1 |
| total | 279 of 300 |
The counts include the first request of each kind, which fires right at startup rather than after a full interval. Every restart costs another four requests on top, which is what the remaining reserve is for.
The default updateInterval of 5 seconds is meant for Modbus and would mean 17280 requests a day
here, so on the API it is raised to 8 minutes and the module logs that it did. Everything else is
taken as configured - if you shorten an interval, do the arithmetic yourself, going over earns you
429 responses for the rest of the day.
Useful numbers when adjusting: 86400 / interval_in_seconds requests per day per endpoint. The
practical floor for the power flow is about 5 minutes, which is what you get with both long
term views switched off - 300 requests a day is one request every 4.8 minutes and no setting
changes that. There is no way to make the API deliver data in real time; that is what the Modbus
source is for.
The live power flow is read straight from the inverters over Modbus/TCP, with no rate limit and no cloud round trip. Enable Modbus/TCP on the leader inverter (SetApp / installer menu) or point the module at a Modbus/TCP proxy:
{
module: 'MMM-SolarEdge',
position: 'lower_third',
config: {
apiKey: "################################",
siteId: "12345",
dataSource: "modbus",
updateInterval: 1000 * 10,
modbus: {
host: "192.168.1.20",
inverterUnitIds: [1, 2, 3] //leader first, then the followers
}
}
}The module reads the inverters, the export/import meter and the batteries, and derives the same power flow the API returns. Details, overview and day energy still come from the API - they add up to fewer than 200 requests a day and stay well inside the quota.
Sites without a battery need no configuration for it. The module notices that there is no storage, drops the battery from the display and stops asking for it, exactly as it does when the API reports a site without storage. The same goes for a site without an export/import meter, except that the grid then reads zero, because there is nothing left to measure it with.
Note that each Modbus read travels the RS485 chain between the inverters. Nameplate data is read
once and cached, after which a full cycle over three inverters plus meter and batteries takes
roughly two seconds. Setting updateInterval much below that only queues up reads without
delivering fresher data.
| Option | Description |
|---|---|
apiKey |
Required An API Key that can be obtained by creating one in your SolarEdge Monitoring Portal https://monitoring.solaredge.com |
siteId |
Required The Site ID of the SolarEdge system you wish to monitor, which can be found in the Dashboard https://monitoring.solaredge.com |
dataSource |
Optional "api" (default) or "modbus", see above |
updateInterval |
Optional How often the power flow is fetched, default is 5000. Applied as is over Modbus. On the API anything below 8 minutes is raised to 8 minutes, otherwise a single day would blow the request limit - the module says so in the log |
updateIntervalBasicData |
Optional Update interval for overview and day energy, default is 30 minutes |
portalUrl |
Optional override in case of a proxy, default is https://monitoringapi.solaredge.com |
showOverview |
Optional Enables/disables the long term data view, default is true |
showDayEnergy |
Optional Enables/disables the day energy data view, default is true |
decimal |
Optional The decimal symbol that will be used to display numbers. Possible values are "comma" or "period". Default is comma. |
mockData |
Optional Serve mock data instead of talking to the real API, default is false. "pvbatt" mocks a site with a battery, "pv" one without |
| Option | Description |
|---|---|
modbus.host |
Required for Modbus Address of the leader inverter or of a Modbus/TCP proxy |
modbus.port |
Optional default is 1502, the SolarEdge default |
modbus.inverterUnitIds |
Optional Modbus unit ids to read, default is [1]. List the leader first, then the followers |
modbus.meterUnitId |
Optional Unit that carries the export/import meter, defaults to the first entry of inverterUnitIds |
modbus.invertGridSign |
Optional Set to true if import and export show up swapped, default is false. The module compares the live sign against the meter's energy counters and warns in the log when they disagree |
modbus.flowThreshold |
Optional Power in watts below which a flow counts as zero, default is 10. Raise it if arrows flicker around zero, lower it to see even the smallest trickle into the grid |
modbus.timeout |
Optional Timeout per Modbus read in milliseconds, default is 5000 |
The battery and the strings are metered on the DC side of the inverter, the house and the grid meter on the AC side. Read as they are, the battery always looks like it delivers a percent or two more than the house consumes - that difference is simply the inverter's conversion loss on the way from DC to AC.
The module therefore scales the DC readings onto the AC side using the conversion ratio the inverters are measurably running at, which is what the monitoring API reports as well. PV, storage and grid then add up to the load exactly instead of leaving an unexplained remainder.