A standalone Python library that reads and controls Growatt solar inverters over Modbus, exposed as a normal, object-oriented Python API.

The register maps are based on homeassistant-solax-modbus (Apache-2.0), whose Growatt plugin they are extracted from. This library keeps that project's licence and is a derived work of it.

Design

  • It consumes the connection abstraction, not a backend: you build a modbus_connection.ModbusUnit and hand it over. You choose and own the transport.
  • Five generations, five register maps. Growatt's protocol generations are not layers on one map — the same input register means one thing on an SPF and something else on a MIN TL-XH. Each generation therefore has its own device class and its own components, so an attribute always means what its name says.
  • A model only reads the registers it has. Every field carries the allowedtypes mask it has upstream; the inverter's Variant bits (phase count, PV / AC / hybrid, MPPT count, backup output, dry contact box) select the subset at construction, via restrict_fields. This is not cosmetic: a Modbus block read is atomic, so one register the inverter does not serve would fail every field sharing its block.
  • Status and settings refresh separately. async_update_status() reads what the inverter measures, async_update_settings() what it has been told to do, and async_update() does both — so a consumer can put the configuration registers on a slower schedule without reimplementing the poll.
  • Settings are writable, by the same names they are read under — a label for a mode, a datetime.time for a schedule slot, a number for a limit. Ranges are validated before anything reaches the inverter, and a setting packed into part of a register is written read-modify-write, so its neighbours survive.

Supported inverters

Generation Models Class Fields
GEN Legacy PV: TL-S, TL3-S, NEO Gen1Inverter 46
GEN2 MOD / MID TL3-X PV Gen2Inverter 77
GEN3 SPH, SPA storage Gen3Inverter 192
GEN4 MIN / MOD / MID / WIT TL-XH hybrid, TL-X PV Gen4Inverter 322
SPF SPF, SPE off-grid SpfInverter 69

detect() identifies the generation and the model's options from the serial number, using the same prefix tables as upstream — 63 serial prefixes and 20 firmware prefixes, covering MIN, MOD, MID, MAX, MIC, SPH, SPA, SPE, SPF, WIT and NEO families.

Within a generation, the Variant bits decide which fields exist:

Bits Selects
X1 / X3 single- or three-phase grid registers
PV / AC / HYBRID / MIC inverter category
MPPT3 … MPPT10 PV strings beyond the two every model has
EPS the backup-output registers
DCB the dry-contact-box registers
APX the APX HV battery's own register bank

EPS and DCB are opted into (detect(read_eps=True)). APX is detected: a Gen4 hybrid reads the BMS type the inverter reports and only then polls the 29 blocks the APX bank spans, because a hybrid with an LG or ARK pack refuses every one of them. detect(read_apx=True) forces it on for a device that misreports.

Use

import asyncio
from modbus_connection import ModbusTcpParams
from modbus_connection.tmodbus import ModbusConnection
from growatt_modbus import Gen4Inverter, detect


async def main() -> None:
    conn = ModbusConnection(ModbusTcpParams(host="192.168.1.50", framer="rtu"))
    try:
        inverter = await detect(conn.for_unit(1), read_eps=True)
        assert isinstance(inverter, Gen4Inverter)  # a MIN TL-XH, say
        await inverter.async_update()

        print("Serial:", inverter.serial_number)
        print("Variant:", repr(inverter.variant))
        print("PV1 power:", inverter.hybrid_status.pv_power_1, "W")
        print("Battery SOC:", inverter.hybrid_status.battery_soc, "%")
        print("Battery power:", inverter.battery_combined_power, "W")
        print("Fault:", inverter.inverter_fault_text)

        # Settings are written by the same names they are read under.
        await inverter.hybrid_settings.write("ems_charging_rate", 80)
        await inverter.hybrid_settings.write("time_1_mode", "Battery First")
    finally:
        await conn.close()


asyncio.run(main())

If you already know the model, skip detection:

from growatt_modbus import Variant, build

inverter = build(unit, Variant.SPF | Variant.HYBRID | Variant.X1, "KAM0000001")

detect() returns whichever device class matches the inverter it found, so narrow it (with isinstance, or match) before reaching for a generation's own sub-systems.

Passing the serial number matters for the handful of models whose registers a prefix rules out — a KAM-series SPF has one PV input, so its PV2 registers are never read.

Polling one sub-system

Each sub-system is an independently updatable component with its own listeners:

await inverter.hybrid_status.async_update()  # just the live measurements
unsub = inverter.hybrid_status.add_update_listener(refresh_my_entity)

inverter.async_update() refreshes each of them in turn — 2 requests for an SPF, 20 for an SPH, 25 for a MIN TL-XH and 54 with an APX battery, none wider than the 100 registers the inverter answers.

Polling the settings apart from the readings

The *_status components hold what the inverter measures; the *_settings components hold what it has been told to do, and change only when something writes them. Each group has its own method, so the settings can go on a slower schedule and be read back on demand after a write:

await inverter.async_update_status()  # every cycle
await inverter.async_update_settings()  # rarely, and after a write

await inverter.hybrid_settings.write("ems_charging_rate", 80)
await inverter.async_update_settings()  # read back what took effect

async_update() is unchanged: it does both, in one report.

What that takes off the fast schedule is most of the poll's width — 1 request of an SPF's 2, 3 of a Gen2's 9, 7 of an SPH's 20, 11 of a MIN TL-XH's 25, and 25 of the 53 an APX hybrid issues (205 registers of its 838). The APX battery's fifteen serial numbers and monitoring versions ride with the settings: they change less often still, and twelve of them are islands 40 registers apart that cost a request each. Module 1's live readings are battery_module_1_status and stay on the fast side.

Poll the settings at least once at startup even if the consumer only wants readings: firmware_control_version comes from settings, and Gen4Inverter.battery_voltage scales itself from a hybrid_settings field.

Partial updates

A poll reads each sub-system independently, the way the integration reads its blocks: one slow or refused block does not take the rest of the poll with it. Every update method returns an UpdateReport — a failed component keeps its previous values, does not notify its listeners, and is listed by attribute name with its error, while every other component refreshes and notifies once that poll is done. A report names only what the method it came from polled, and a settings poll fires its own components' listeners when that call is done, so it does not hold up the readings; async_update() is one cycle and one notification, firing nothing until both halves have been read. A dead link (ModbusConnectionError) raises, and so does a timeout on the very first component: nothing answered at all, so the inverter is asleep or unreachable and walking the rest would only pay a timeout each. Once any component has answered — refreshed or refused — a later timeout is contained like any other failure:

report = await inverter.async_update()
for name, error in report.failed.items():
    print(f"{name} kept its previous values: {error}")

Connection

Growatt inverters speak Modbus RTU on RS-485, reached either directly over serial or through a transparent RTU-over-TCP gateway (hence framer="rtu" on a TCP connection above). The library never opens a connection itself — it takes the ModbusUnit you give it.

ASCII framing over TCP is not supported. Do not construct the connection you hand this library with framer="ascii"; the register semantics here assume RTU or socket framing, and ASCII-over-TCP is out of scope.

Checking a real inverter

script/query.py identifies the inverter, reads it once and prints everything it has, which is the quickest way to see whether one is wired and addressed correctly:

uv run script/query.py /dev/ttyUSB0 --transport serial --unit 1
uv run script/query.py 192.168.1.50 --unit 1 --framer rtu

It prints the detected variant and the read count as well, so what this inverter turned out to be — and how few requests its poll takes — is visible against real hardware rather than only in the tests. Add --eps, --dcb or --apx to bring in the register groups those options carry.

Scope

Every entity in the upstream Growatt plugin that carries register knowledge is modelled — 616 sensor and 145 writable declarations, translated mechanically and then checked back against the source field by field on address, register space, word count, scale, signedness, option map and writability.

Two things upstream does are deliberately not carried over, because they are Home Assistant concerns rather than device knowledge: entity presentation (icons, device classes, entity categories, translation keys), and the UI-local state behind the Gen4 time-slot editor. The slot registers themselves are modelled directly — start time, end time, priority mode and the enable bit are four fields over the two registers the inverter actually has, so the upstream "update" and "clear" buttons are not needed. The upstream buttons that do write a register (clock sync, and the "not limited" power-limit command) are modelled as writable fields instead.

Where upstream declares one key twice within a single generation, at two different registers, both are kept here under distinct names — the collision is real, and dropping either would lose a register:

  • inverter_temperature (input 93) and inverter_temperature_alt (input 32) on Gen2;
  • battery_type (holding 1048, the setting) and battery_type_reported (input 119, the reported value, with a different code map) on Gen3.

Develop / test

uv sync
uv run pytest
uv run ruff check . && uv run ruff format --check . && uv run mypy

Tests run against the in-memory mock backend that ships with modbus-connection (its mock_modbus_unit pytest fixture) — no hardware, no Modbus server, and no Home Assistant.

About

Read and control Growatt solar inverters (MIN/MOD/MID/MAX/SPH/SPA/WIT/SPF) over Modbus (based on homeassistant-solax-modbus)

Resources

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages