Skip to content

RT-Struct does not always align with the original CT Scan #114

Description

@Joshua-Roche

I have a deep learning model that segments a DICOM-formatted CT scan. The segmentation is saved out as a numpy array. When I try to convert this array to an RT-Struct, providing the folder that the CT scan lies in and the numpy array and overlay this RTStruct in DICOM-Viewing Software, the segmentation is not in the correct place, but offset ~120 slices (this offset number changes for every scan).

I've had real trouble with these CT scans.

Josh

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions